
Industrial Water Analyser
Match online wet-chemistry measurement to the parameter, sample matrix and control decision in an industrial water system.
Industrial water is part of the process
Industrial water duties span incoming water, treatment stages, boilers, cooling circuits, rinse systems, scrubbers, wastewater and final effluent. Each location presents a different analytical question and sample condition.
PMA starts with the decision the measurement must support, then reviews analyte, range, sample handling, cycle time, outputs and verification requirements.
Turn the process question into a measurement duty
A practical application review should define:
- The measurement location and the process decision it supports.
- The analyte, reporting form, normal range and upset range.
- Sample temperature, pressure, flow and materials compatibility.
- The number of streams and required analysis cycle time.
- Control-system outputs, alarms and data-recording requirements.
- Calibration, verification, reagent and maintenance responsibilities.
These details allow the analyser chemistry, sample system and installation to be reviewed as one maintainable package.

Three questions shape the analyser duty
01
What must be measured?
Define the parameter, chemical form, normal range and upset conditions.
02
Where will the sample come from?
Document pressure, temperature, flow, solids, colour and chemical additions at the proposed take-off.
03
What happens after the result?
State whether the result informs trending, dosing, endpoint control, alarm response or compliance investigation.
Configure chemistry around the application
AccuSeries can automate colorimetric, titrimetric or ion-selective electrode methods where a suitable method is available for the concentration and matrix.
Acid Concentration
Monitor mineral and process acid concentration online for tighter control of industrial treatment and manufacturing duties.
Caustic Concentration
Measure caustic or sodium hydroxide concentration where chemical strength supports dosing, cleaning or production control.
Silica
Track silica in treated water, boiler-water and process applications using configured online colorimetry.
Chloride
Monitor chloride where water quality, corrosion risk or process chemistry requires a parameter-specific result.
Application boundaries
Method performance depends on representative sampling, controlled conditions, suitable reagents and known interferences. Sample conditioning must be designed without changing the measurand.
Online measurement supports the operating decision. It does not replace statutory sampling, accredited laboratory work or application-specific verification.
Build a usable industrial-water brief
Provide the chemistry and process context together.
- Parameter and reporting units.
- Expected minimum, normal, maximum and upset values.
- Process location and reason for measuring.
- Sample composition, temperature, pressure, flow and solids.
- Known interferences, additives and cleaning chemicals.
- Required outputs, alarms, cycle time and verification method.
Turn the industrial measurement need into a specification
Share the process objective, parameter, operating range and sample constraints. PMA can review the method, sample conditioning, analyser configuration, outputs, installation and support as one application-led system.
