AccuSeries Online Wet Chemistry Analyser
The AccuSeries multi-parameter analyser combines colorimetry, titration and ion-selective electrode methods with programmable sampling, calibration and cleaning for wastewater and industrial processes.
Programmable online chemistry in a modular analyser
The programmed sequence captures a consistent sample, adds reagents and reports each result while operators monitor status through the graphical interface.
01 / FLEXIBLE METHODS
Colorimetry, titration and ISE analysis
AccuSeries is configured around the required parameter, range, sample matrix and recognised analytical method.
- Multi-parameter programming
- Multi-stream sampling
- Method-specific result calculation
02 / AUTOMATIC OPERATION
Sampling, calibration and cleaning
Programmable routines support repeatable operation while diagnostics and alarms alert users to changing analyser or process conditions.
- Automatic sampling
- Automatic calibration
- Automatic cleaning
Core AccuSeries information
General specifications vary with the configured method and should be confirmed for the selected application.
Typical analysis time
3โ15 min
Sample streams
Up to 6
Protection grade
IP66
Power supply
90โ240 VAC
Approximate weight
45 kg
Automatic functions
3
A controlled wet-chemistry sequence
AccuSeries completes each stage using the configured sample handling, reagents, method and calibration.
01.
Capture the sample
The internal fast loop and sample mechanism provide a representative, consistent volume for analysis.
02.
Add the reagents
The programmed sequence introduces the reagents required for the selected method.
03.
Run the method
The programmed colorimetric, titration or ISE method proceeds under controlled conditions.
04.
Measure and calculate
The measured optical or electrode response is converted into the configured concentration result.
05.
Calibrate
Automatic calibration can run against configured standards at selected intervals.
06.
Clean
Automatic cleaning supports the measurement system between planned maintenance visits.
One modular analyser. Broad process-analysis capability.
Compare colorimetric analysis, online titration, ion-selective electrode measurement and multi-stream, multi-parameter analysis. Then review the available chemistries or contact PMA to discuss your sample, measuring range and process objective.
Features
- Multi-stream capability
- Graphical operator interface
- Programmable analysis methods
- Colorimetry, titration and ISE
- Modular wet-chemistry system
- Narrow 16-inch footprint
- Diagnostics and alarms
- Automatic sampling, calibration and cleaning
- Custom-selected wetted parts
- Advanced sample conditioning options
- IP66 / NEMA 4X enclosure
- Div. 2 and Zone 2 options
Applications
- Municipal water and wastewater
- Industrial wastewater effluent
- Chemical and chlor-alkali processes
- Refining and petrochemicals
- Semiconductor manufacturing
- Power and boiler-water treatment
- Gas scrubbing and abatement
- Food and beverage processes
- Pulp and paper processing
- Plating and metals treatment
- Pharmaceutical processes
- Process-water optimisation
- Wastewater treatment control
- Drinking-water analysis
- Laboratory method matching
Parameters
- Aluminium
- Ammonium / ammonia
- Chloride
- Chlorine
- Chromium(VI)
- Copper
- Formaldehyde
- Hardness
- Hydrazine
- Iron
- Manganese
- Nickel
- Nitrite
- Phenol
- Phosphate
- Silica
- Sulphate
- Zinc
The available measuring range and method depend on the selected chemistry and sample conditions. Confirm the required configuration with PMA before specification.
Designed for practical industrial operation
The modular AccuSeries design keeps wet-chemistry components accessible while measurements, diagnostics and method controls remain available through the interface.
Touchscreen
Clear access to measurements, status and analyser functions.
Data logging
Integrated storage with USB export.
Separate compartments
Electronic and wet sections are physically separated.
Low reagent use
Small reagent volumes help control consumable costs.

Built for demanding water and process analysis
01
Automatic sampling
A repeatable sample-capture routine supports representative analysis across configured streams.
02
Automatic calibration
Validation can be scheduled to provide a regular check of analyser response.
03
Automatic cleaning
Programmed cleaning supports the measurement system between planned visits.
04
Flexible methods
Colorimetric, titration and ISE methods are configured around the application.
05
Multi-parameter analysis
Multiple compatible analytes can be monitored with one configured analyser.
06
Programmable operation
Analysis frequency and method can be configured around the selected chemistry.
07
Process connectivity
Modbus, Ethernet and 4โ20 mA options connect results with plant control systems.
08
Multi-stream sampling
Configurable stream sequencing helps one analyser serve multiple sample points.
09
Modular design
Plug-and-play modules and accessible fluidics support practical maintenance.
Technical specifications
Core AccuSeries LPA information for application and specification review.
| Measurement principle | Spectroscopic colour-development reactions |
| Variables | Parameter dependent; approved method |
| Analysis frequency | Approximately 6 to 20 minutes |
| Power supply | 110-230 VAC, 50/60 Hz, 80 VA |
| Operating temperature | 5 to 45ยฐC |
| Cabinet | Epoxy-coated stainless steel |
| Protection grade | IP54 |
| Outputs | 2 x 4-20 mA; Modbus according to configuration |
| Automatic functions | Calibration, validation and cleaning |
Specifications should be confirmed against the latest AccuSeries documentation for the configured method before procurement.

Where AccuSeries can be used
The correct configuration depends on the analyte, concentration range, sample matrix, required method and process objective.
Wastewater and effluent
Online multi-parameter chemistry for municipal wastewater, industrial effluent and challenging samples.
Chemical and process industries
Configurable measurement for chemical, refining, gas-abatement, plating and manufacturing processes.
Water, power and utilities
Flexible wet-chemistry analysis for drinking water, boiler water, cooling water and treatment duties.
Online measurement does not replace required laboratory analysis
Accredited laboratory analysis and statutory sampling remain necessary where required by the application or regulation.
AccuSeries Application Notes
Explore four practical application notes showing how AccuSeries supports demanding water and process measurements. Review more AccuSeries applications or contact PMA to discuss your process.
Refinery wastewater effluent monitoring
Track alkalinity, ammonia, nitrate and selected metals in refinery effluent using automated AccuSeries wet chemistry.
CMP wastewater treatment in semiconductor manufacturing
Monitor hydrogen peroxide, copper, acidity and alkalinity in CMP wastewater to support treatment control.
Sour-water stripping in a refinery
Measure ammonia, sulphide, phenol or cyanide around sour-water stripping processes.
Caustic scrubber control and measurement
Monitor caustic concentration directly to improve scrubber control and reduce reliance on pH alone.
Which wet-chemistry method does AccuSeries use?
AccuSeries can use colorimetry, color titration, potentiometric titration, ion-selective electrodes or direct measurement according to the application.
How is sample colour managed?
Dual-wavelength colorimetry and automatic blanking can compensate for background colour and turbidity in suitable methods.
Can methods match laboratory procedures?
Methods can be configured around recognised EPA, ISO or ASTM procedures and application-specific requirements.
Why does application review matter?
Sample matrix, analyte, range, interferences and process objectives determine the right method and configuration.