Online Phenol Analyser

AccuSeries LPA online wet chemistry analyser

Online Phenol Analyser with AccuSeries

AccuSeries can automate colorimetric phenol measurement for suitable refinery, industrial process-water and effluent applications. The required range, sample preparation and potential interferences determine the final method. Read PMA’s independent phenol application guide for wider measurement context.

An approved AccuSeries reference setup covers 0–20 ppm phenol using a modified antipyrine colorimetric method with dilution, two reagent additions and controlled colour-development time. PMA verifies whether that range and chemistry fit the live sample before specification. Explore the refinery sour-water application guide and colorimetric analyser hub.

Programmable online phenol analysis

The approved 0–20 ppm reference method uses modified antipyrine chemistry. The configured sequence dilutes a small captured sample, adds 4-aminoantipyrine and ammonium persulfate reagents, then allows the colour to develop before optical measurement.

01 / CONFIGURED METHOD

Modified antipyrine colorimetry

Range, dilution, reagent volumes and colour-development time are configured together; they cannot be selected independently of the sample matrix.

  • Reference range of 0–20 ppm for the documented setup
  • 500 nm measurement with 810 nm optical reference
  • Controlled dilution and ten-minute final colour development

A controlled phenol measurement sequence

Each phenol result follows a configured sampling, reagent, measurement, calculation and maintenance sequence.

01.

Capture the sample

The internal fast loop and sample mechanism provide a representative, consistent sample volume for phenol analysis.

02.

Add method reagents

The programmed sequence doses the reagents required for the selected phenol method.

03.

Run the configured method

The approved phenol method proceeds under controlled conditions.

04.

Calculate the phenol result

The measured response is converted into the configured phenol concentration result.

05.

Calibrate

Automatic calibration can run against configured phenol standards at selected intervals.

06.

Clean

Automatic cleaning supports the phenol measurement system between planned maintenance visits.

Phenol-specific configuration checks

The documented reference setup demonstrates how range, dilution, optical path and reaction time are engineered as one complete phenol method.

Range and dilution

Confirm whether the expected phenol concentration fits the validated method range.

Colour development

Allow the programmed reaction time required for the final optical response.

Optical materials

Review probe, reflector and wetted materials against the sample.

Reagent plan

Plan dilution water, antipyrine reagent, persulfate reagent and standards.

PMA engineer supporting an AccuSeries online analyser

Phenol technical specifications

Core AccuSeries information for phenol application and specification review.

Measurement principleApplication-specific approved method
VariablesPhenol, range and sample matrix dependent; approved method
Typical responseT-90 typically 3 to 15 minutes; method dependent
Power supply24 VDC or 90 to 240 VAC; 310 W
SamplingSingle stream or up to 6 streams
CabinetPainted 304 stainless steel
Protection gradeIP66; NEMA 4X
Outputs4-20 mA; optional Modbus TCP/IP or serial
Automatic functionsSampling, calibration, validation and post-wash as configured

Phenol, range, sample conditions, wetted materials and final specifications must be confirmed for the configured method before procurement.

Win A Google Pixel Tablet

Tablet display showing a three-dimensional measurement interface

From pH panels to sludge settlement analysers, PMA delivers the instrumentation and support your facility relies on. We are currently offering a Google Pixel Tablet to one lucky operator who contacts us to discuss a project or service requirement.

Terms and conditions apply. Prize draw entry requires a valid enquiry regarding PMA Ltd products or services. Valid for UK and Ireland residents only.


This form collects your name, contact details, company and enquiry information so the PMA AccuSeries team can respond to you. Please see our Privacy Policy for how we protect and use your data.