Online Iron Analyser

AccuSeries LPA online wet chemistry analyser

Online Iron Analyser with AccuSeries

AccuSeries can automate online iron analysis for suitable drinking-water, process-water and wastewater applications. Configurable colorimetry supports treatment monitoring, coagulant control and final-water or effluent checks between laboratory results. For municipal wastewater duties, review iron monitoring at sewage treatment works. PMA also provides an independent iron application guide for wider measurement context.

An approved iron and manganese configuration uses separate Ferrozine and PAN colorimetric chemistries with a shared calibration pump and optical measurement at 550 nm against an 810 nm reference. PMA confirms range, matrix, oxidation state and interference controls before specification. Read why sites may monitor iron after ferric dosing for phosphorus removal, then explore the AccuSeries platform and online colorimetric analyser guidance.

Iron monitoring at sewage treatment works

Where iron-based chemicals support phosphorus removal, a frequent iron result can help investigate dosing performance, residual-metal trends or a developing final-effluent change. The measurement must be matched to the required iron basis and the actual wastewater matrix.

Define the operator response, sample location and verification method before selecting the configuration. The dedicated application guide explains the questions PMA will review.

Confirm before selection

  • Required iron fraction and units
  • Normal and upset concentrations
  • Solids, colour and treatment chemicals
  • Reference method and sample preparation
  • Sampling point and operating response

Programmable online iron analysis

The approved multi-parameter configuration measures iron with Ferrozine colorimetry after pH control and reduction chemistry. A 550 nm measurement filter and 810 nm reference filter support the optical result.

01 / CONFIGURED METHOD

Ferrozine colorimetry for iron

Method setup controls pH, reagent sequence, optical path and the iron range required by the process decision.

  • Ferrozine colour-development chemistry
  • 550 nm measurement with 810 nm optical reference
  • Optional iron and manganese multi-parameter configuration

A controlled iron measurement sequence

Each iron result follows a configured sampling, reagent, measurement, calculation and maintenance sequence.

01.

Capture the sample

The internal fast loop and sample mechanism provide a representative, consistent sample volume for iron analysis.

02.

Add method reagents

The programmed sequence doses the reagents required for the selected iron method.

03.

Run the configured method

The approved iron method proceeds under controlled conditions.

04.

Calculate the iron result

The measured response is converted into the configured iron concentration result.

05.

Calibrate

Automatic calibration can run against configured iron standards at selected intervals.

06.

Clean

Automatic cleaning supports the iron measurement system between planned maintenance visits.

Iron-specific configuration checks

The iron result depends on the defined analytical form, reduction chemistry, sample colour or turbidity and the required process response.

Iron basis

Confirm the iron species or preparation represented by the reported result.

Optical reference

Review background colour and turbidity against the dual-wavelength method.

Combined analysis

Assess whether iron and manganese can share one configured platform.

Reagent control

Plan buffer and Ferrozine preparation, calibration standards and consumption.

PMA engineer supporting an AccuSeries online analyser

Iron technical specifications

Core AccuSeries information for iron application and specification review.

Measurement principleApplication-specific approved method
VariablesIron, range and sample matrix dependent; approved method
Typical responseT-90 typically 3 to 15 minutes; method dependent
Power supply24 VDC or 90 to 240 VAC; 310 W
SamplingSingle stream or up to 6 streams
CabinetPainted 304 stainless steel
Protection gradeIP66; NEMA 4X
Outputs4-20 mA; optional Modbus TCP/IP or serial
Automatic functionsSampling, calibration, validation and post-wash as configured

Iron, range, sample conditions, wetted materials and final specifications must be confirmed for the configured method before procurement.

Discuss your iron measurement

Tell PMA about your sample, measuring range, process objective and reference method. An applications engineer will review whether AccuSeries and an available analytical method are appropriate.

Win A Google Pixel Tablet

Tablet display showing a three-dimensional measurement interface

From pH panels to sludge settlement analysers, PMA delivers the instrumentation and support your facility relies on. We are currently offering a Google Pixel Tablet to one lucky operator who contacts us to discuss a project or service requirement.

Terms and conditions apply. Prize draw entry requires a valid enquiry regarding PMA Ltd products or services. Valid for UK and Ireland residents only.


This form collects your name, contact details, company and enquiry information so the PMA AccuSeries team can respond to you. Please see our Privacy Policy for how we protect and use your data.